GE Aritech ATS series alarm panel connections and configuration using the
WebWay RS232 interface
ATS 3000/4000/4500 series
The ATS panel will require the ATS1801 serial interface module
Connect the WebWay panel interface 232 T, R, PWR - (Ground) and PWR + to the Computer port RXD, TXD, GND
and CTS (+12 Volts) on the ATS panel – note T to RXD and R to TXD. As the Webway can draw power from this
connection there is no need for additional wiring.
Aritech ATS series panel configuration
Select advanced service menu
Got to menu 9
Ensure PBX is blank
Ensure MSN is blank
Select Dial tone detection <UK>
Select DTMF tone dialling <YES>
Select Enable PSTN line fault monitor <NO>
Select Monitor Service tones <NO>
Select Use 3 digit SIA extensions <YES>
Select ISDN point to point <NO>
Select 200 baud reverse area open/close <NO>
Select X25 TEI value <2>
Select Audio listen in time <180>
Select Audio listen in frame time <30>
Select Report mains fault <YES>
Select Report line fault <YES>
Select Enable GSM line fault monitor <NO>
Select the central station to program <Central station 1>
Select the reporting format <X-SIA Large> (Option 7)
Enter the first phone number <01234 567890> (any valid phone number is acceptable)
Enter the system account number <______> (Site ID/Account Number)
Select BELL modem tones for SIA <YES>
Enter the Area account number <______> (Site ID/Account Number)
Select Dual reporting <NO>
Select Listen in <NO>